Single excitation band fiber photometry measurements use an FMC with 3 ports: one port for the excitation light, one for the fluorescence detection, and one to connect to the sample. The cube has a dichroic mirror to let the excitation light through and separate the fluorescence emission and narrow bandpass filters to limit the excitation or fluorescence spectrum. E stands for fluorescence excitation, F for fluorescence, and S for the sample port on the cube's schematic. Currently, only Green Fluorophore (GFP-like) configurations or Red Fluorophore (RFP-like) are offered. Still, the filter set can be customized for other fluorophores on request.

The Intensity Adjustment Ring on the 460-490 nm LED light source reduces the source power below the LED driver's range if needed for low-power fiber photometry experiments.

Compared to Fluorescence Mini Cubes with only FC connectors on all ports, the ones with integrated photodetectors provide a 100% better signal-to-noise ratio (30% signal increase and a 40% noise reduction). Moreover, the versions where LEDs are integrated as well reduce the number of optical connections and the system’s overall footprint.

Mini Cube
   Wavelength range   350 to 1100 nm
   Optical fiber compatibility - Core diameter 200 or 400 µm
- NA 0.37 to 0.57
   Spectral bandwidth Green Fluorophore :
- Excitation 460-490 nm
- Emission 500-550 nm

Red Fluorophore :
- Excitation 540-570 nm
- Emission 580-680 nm
   Optical filter attenuation > OD 5 outside band
   Dimensions   57 mm x 63 mm x 26 mm
Built-in Detectors
   Detector Sensitivity - 0.38 A/W @ 550 nm
- 0.60 A/W @ 960 nm (peak)
   Amplification   3 levels : 1x, 10x, 100x
   Transimpedance gain - 2.0 E09 V / A (1x)
- 2.0 E10 V / A (10x)
- 2.0 E11 V / A (100x)
   Conversion gain
   @ 550 nm
- 0.76 V / nW (1x)
- 7.60 V / nW (10x)
- 76.0 V / nW (100x)
   Saturation level
   @ 550 nm
- 7.2 nW (1x)
- 0.72 nW (10x)
- 72 pW (100x)
   NEP < 12 fW/√Hz
   Bandwidth - DC : 0 - 1000 Hz
- AC : 30 - 1000 Hz
   Electrical interface   BNC
   Output Voltage   0.0 to 5.5 V
   Output impedance   50 Ω
   Sensor type   Silicon photodiode
   Sensor Area   1 x 1 mm
   Input voltage   12 V DC (power supply included)
Built-in LEDs (ilFMC Gen.2)
   Max Current   500 mA
   Emitter size   400 µm diameter - NA0.22
   Max Output Power
   (fibre 400  µm)
  LED 460-490 nm
= 1.5 to 120 µW (adjustable) 
  LED 540-570 nm
= 50 µW (fixed)
Drawing

Fluorescence Mini Cube 3 ports (FC connector on all ports)

Integrated Fluorescence Mini Cube 3 ports Gen.2 (Built-in DETECTOR)

Integrated LED Fluorescence Mini Cube3 Gen.2 (Built-in LED and DETECTOR)

User ManualFrEn

Integrated Connectorized Fluorescence Mini Cubes

Integrated Fluorescence Mini Cubes - Gen2

Application NoteFrEn

Integrated Fluorescence Mini Cubes - Differences between generation 1 and 2

 

  • Single excitation band fiber photometry measurements use an FMC with 3 ports: one port for the excitation light, one for the fluorescence detection, and one to connect to the sample. The cube has a dichroic mirror to let the excitation light through and separate the fluorescence emission and narrow bandpass filters to limit the excitation or fluorescence spectrum. E stands for fluorescence excitation, F for fluorescence, and S for the sample port on the cube's schematic. Currently, only Green Fluorophore (GFP-like) configurations or Red Fluorophore (RFP-like) are offered. Still, the filter set can be customized for other fluorophores on request.

    The Intensity Adjustment Ring on the 460-490 nm LED light source reduces the source power below the LED driver's range if needed for low-power fiber photometry experiments.

    Compared to Fluorescence Mini Cubes with only FC connectors on all ports, the ones with integrated photodetectors provide a 100% better signal-to-noise ratio (30% signal increase and a 40% noise reduction). Moreover, the versions where LEDs are integrated as well reduce the number of optical connections and the system’s overall footprint.

  • Mini Cube
       Wavelength range   350 to 1100 nm
       Optical fiber compatibility - Core diameter 200 or 400 µm
    - NA 0.37 to 0.57
       Spectral bandwidth Green Fluorophore :
    - Excitation 460-490 nm
    - Emission 500-550 nm

    Red Fluorophore :
    - Excitation 540-570 nm
    - Emission 580-680 nm
       Optical filter attenuation > OD 5 outside band
       Dimensions   57 mm x 63 mm x 26 mm
    Built-in Detectors
       Detector Sensitivity - 0.38 A/W @ 550 nm
    - 0.60 A/W @ 960 nm (peak)
       Amplification   3 levels : 1x, 10x, 100x
       Transimpedance gain - 2.0 E09 V / A (1x)
    - 2.0 E10 V / A (10x)
    - 2.0 E11 V / A (100x)
       Conversion gain
       @ 550 nm
    - 0.76 V / nW (1x)
    - 7.60 V / nW (10x)
    - 76.0 V / nW (100x)
       Saturation level
       @ 550 nm
    - 7.2 nW (1x)
    - 0.72 nW (10x)
    - 72 pW (100x)
       NEP < 12 fW/√Hz
       Bandwidth - DC : 0 - 1000 Hz
    - AC : 30 - 1000 Hz
       Electrical interface   BNC
       Output Voltage   0.0 to 5.5 V
       Output impedance   50 Ω
       Sensor type   Silicon photodiode
       Sensor Area   1 x 1 mm
       Input voltage   12 V DC (power supply included)
    Built-in LEDs (ilFMC Gen.2)
       Max Current   500 mA
       Emitter size   400 µm diameter - NA0.22
       Max Output Power
       (fibre 400  µm)
      LED 460-490 nm
    = 1.5 to 120 µW (adjustable) 
      LED 540-570 nm
    = 50 µW (fixed)
  • Drawing

    Fluorescence Mini Cube 3 ports (FC connector on all ports)

    Integrated Fluorescence Mini Cube 3 ports Gen.2 (Built-in DETECTOR)

    Integrated LED Fluorescence Mini Cube3 Gen.2 (Built-in LED and DETECTOR)

    User ManualFrEn

    Integrated Connectorized Fluorescence Mini Cubes

    Integrated Fluorescence Mini Cubes - Gen2

    Application NoteFrEn

    Integrated Fluorescence Mini Cubes - Differences between generation 1 and 2