Passer au contenu

The Snap-in Imaging Cannula with Fluid Injection has two parallel implants, a GRIN lens for deep-brain imaging, and a fluid channel for liquid injection near the imaging site. The fluid injector is removable to allow for multiple injections.

The Snap-in Imaging Cannula with Fluid Injection is compatible with the following microscopes:


Notes:

• The Fluid Injector for the Multiple Fluid Injections Cannulas must be ordered separately.

• A 2-meter length of polyethylene tubing is sold separately to connect a fluid delivery system to the cannula (PT_OFC_2).

• Each Snap-in Imaging Cannula with Fluid Injection is provided with one of each of the five models of Protrusion Adjustment Rings Model L. If more rings are needed, a set can be purchased separately (PARS_L).

 

    GRIN lens channel
    GRIN lens numerical aperture 0.5
    Working distance 80 µm
    Penetration depth - Type D: 0 - 3.2 mm
    - Type V: 3.0 - 5.6 mm
    - Type E: 5.3 - 8.0 mm
    Diameter 500 µm
    Fluid injection channel
    Injector ID/OD: 100/170 µm
    Guiding tube ID/OD:
    300/410 µm
    Guiding tube protrusion: 500 µm shorter than the GRIN lens
    Plug diameter:
    195 µm
    Plug protrusion: 50 µm longer than the guiding tube
    Fluid connector: 1.25 mm ferrule
    Injector Dead Volume Glass 8 nL/mm fiber length*
    Polyimide 15.4 nL/mm fiber length*
    * fiber length could be find at the end of the Ordering code of the injector
    Drawing

    Snap-in Imaging Cannula with Fluid Injection

    Application NoteFrEn
    Imaging Cannula Implantation & Single-color Microscope Installation
    • The Snap-in Imaging Cannula with Fluid Injection has two parallel implants, a GRIN lens for deep-brain imaging, and a fluid channel for liquid injection near the imaging site. The fluid injector is removable to allow for multiple injections.

      The Snap-in Imaging Cannula with Fluid Injection is compatible with the following microscopes:


      Notes:

      • The Fluid Injector for the Multiple Fluid Injections Cannulas must be ordered separately.

      • A 2-meter length of polyethylene tubing is sold separately to connect a fluid delivery system to the cannula (PT_OFC_2).

      • Each Snap-in Imaging Cannula with Fluid Injection is provided with one of each of the five models of Protrusion Adjustment Rings Model L. If more rings are needed, a set can be purchased separately (PARS_L).

       

      • GRIN lens channel
        GRIN lens numerical aperture 0.5
        Working distance 80 µm
        Penetration depth - Type D: 0 - 3.2 mm
        - Type V: 3.0 - 5.6 mm
        - Type E: 5.3 - 8.0 mm
        Diameter 500 µm
        Fluid injection channel
        Injector ID/OD: 100/170 µm
        Guiding tube ID/OD:
        300/410 µm
        Guiding tube protrusion: 500 µm shorter than the GRIN lens
        Plug diameter:
        195 µm
        Plug protrusion: 50 µm longer than the guiding tube
        Fluid connector: 1.25 mm ferrule
        Injector Dead Volume Glass 8 nL/mm fiber length*
        Polyimide 15.4 nL/mm fiber length*
        * fiber length could be find at the end of the Ordering code of the injector
      • Drawing

        Snap-in Imaging Cannula with Fluid Injection

        Application NoteFrEn
        Imaging Cannula Implantation & Single-color Microscope Installation